PRODUCT SPECIFICATION & CHARACTERISTICS

H & B ThermCon

500 / 600

NEUE_STEINGENERATION_MIT_CRUPE_63_UND_EPS_

APPLICATION AREA

  • FOR HBS PRE CAST SYSTEM – MODULAR HOUSE SYSTEM
  • FOR EXISTING AND NEW BUILDINGS, RENOVATIONS 
  • WALL STRUCTURES: CONCRETE, SAND-LIME, BRICK, POROUS  CONCRETE, FAIR-FACED MASONRY ETC.
  • AS EXTERNAL THERMAL INSULATION COMPOSITE SYSTEM (ETICS)

 

PRODUCT PROPERTIES

  • HIGHLY EFFECTIVE THERMAL, ACOUSTIC & FIRE INSULATION  INCOMBUSTIBLE & NO SMOKE EMISSION
  • PERMEABLE TO WATER VAPOR, HEAT-INSULATING, FIRE – AND SOUND-PROOF  (Please, see DATA TABLE below)

 

APPLICATION

For Exterior and Interior use (In the case of inside application, a dew water calculation is recommendable). Continuously apply in one general direction.

If full width of wall cannot be covered at one time, terminate applications at corners.

ThermCon 500/600

Multi- layer application possible – up to 30 cm

MATERIAL HANDLING

Very good processing properties, machine and mechanical

High layer thicknesses in one go

Processing consistency dependents on the weather.

WORKABILITY TIME

Use mixed ThermCon within 45 minutes.

Do not mix set material again.

CONSUMPTION

Each cm thickness ThermCon 500 – approx. 4,4 kg/m2

Consider Additional consumption for rabbets, holes, wall bags, etc. – In particular for thinner layer thicknesses!

In the case of machine processing the productivity is possibly in a temporary way a little smaller through slight compression of the RECYCLED  EPS beads.

CONDITIONS OF USE

ThermCon is sprayed and can be used manually as well (sprayed i.e. with TURBOSOL Talent/PUTZMEISTER SP11 or similar.

Smaller amounts can be mixed with a hand mixer

Mixing time: Do not exceed 4 – 5 minutes

Mix always the entire bag contents.

The least ThermCon thickness is 2 cm, max thickness up to 40 cm.

Recommended thickness for each layer (slightly wet) is max. 8 cm

It is recommended to establish the max. ThermCon thickness in shifts into slightly wet states.

Leveling ThermCon with the Feather edge.

Avoid intense processing of the fresh ThermCon surface.

After the ThermCon drying time, PF56 I/E exterior plaster can be applied.

STORAGE AND HANDLING

Protect from freezing 32o F (0o C) and temperatures in excess of 90o F (32o C). Store away from direct sunlight.

Protect Portland cement based materials (bag products) from moisture and humidity. Store under cover, off the ground in a dry location.

SHELF LIFE

6 to 9 months, if properly stored and sealed.

EXAMINATION

Inspect Concrete and masonry surfaces for:

  • Contamination – algae, chalkiness, dirt, dust, efflorescence, form oil, fungus, grease,  laitance, mildew or other foreign substances.
  • Surface absorption and chalkiness.
  • Cracks – measure crack width and record location of cracks.
  • Damage and deterioration.
  • Moisture damage – record any areas of moisture damage.

Surfaces must be free of all bond-inhibiting materials, including dirt, efflorescence, form oil and other foreign matter. Loose or damaged material must be removed and repaired.

Report deviations from the requirements of project specifications or other conditions that might adversely affect the ThermCon application, to the General Contractor.

SITE CONDITIONS

Hot or very dry conditions accelerate drying and moisture loss from ThermCon which can affect resistance to cracking.

Adjustments in the application, scheduling and curing of ThermCon to prevent rapid loss of moisture are necessary to achieve a satisfactory ThermCon application result.

Cold temperatures retard drying and adjustments may have to be made in the application, scheduling to prevent application damage from frost and other trades.

Do not install or protect ThermCon during extremely hot, dust, dirt, rain, freezing, dry and/or continuous windy conditions.

Do not install ThermCon during freezing conditions or on frozen substrates. Allow final ThermCon application to completely dry before applying finish.

Moisture from concrete may delay the application until 28 days after the concrete is placed.)

After satisfactory inspection of surfaces and correction of any deviations from specification requirements commence the ThermCon application.

 

DATA SHEET

Transport  –    No special protective measures or hazardous goods markings are necessary.

Disposal    –     Dispose of in accordance with local, state or federal regulations.

Clean Up   –     Clean tools and equipment with water immediately after use. Dried material can only be removed mechanically.

Health Hazard Information:

Health Effects

No adverse health effects expected if the product is handled in accordance with this Safety Data Sheet and the product label.

Symptoms that may arise if the product is mishandled are:

Acute effects

Swallowed:     Ingesting large amounts may result in nausea and minor discomfort.

Eye:                 Any fine dust may be an eye irritant.

Skin:                Contact with skin may result in irritation. Repeated or prolonged skin contact may lead to irritant contact dermatitis.

Inhaled:           Inhalation of dust may result in respiratory irritation.

First Aid

Swallowed:     Rinse mouth with water. Give plenty of water to drink. Seek medical advice

Eye:                 Irrigate with copious quantities of water for fifteen minutes. In all cases of eye contamination it is a sensible precaution to seek medical advice.

Skin:                Wash contaminated skin with plenty of water. If irritation occurs seek medical advice.

Inhaled:          Remove victim from exposure. Seek medical advice if effects persist.

 

UPDATES AND CURRENT INFORMATION

The information in this document may change without notice.

Further information:     info@hbasia.hk or your local distributor